Connect meters & sensors to your Wildeye using a range of attachment accessories as shown in the diagram below.
- Many meters & sensors are available from Wildeye that have pre-fitted plugs. If you are connecting to an existing meter/sensor, choose between the standard M12 Field Connect or M12 Bare Wire accessories to attach your meter/sensor to the Wildeye cable.
- Most Standard Wildeye Models have interface cables that contain multiple channels. Use splitter accessories to physically connect multiple meters/sensors to a single Wildeye cable.
- If extra cable length is required, choose from a range of off-the-shelf waterproof cable extension options.
- If additional channels are required, add an expander module to any Wildeye cable containing an "S" channel.
Meter & Sensor Attachment Options
|
Product Code |
Image |
Description |
Application |
ACC-CON-M12-5POS-M-3ACC-CON-M12-5POS-M-6ACC-CON-M12-5POS-M-8 |
|
M12 Field Connect Male, 5-position. Options for cable sizes: 3mm, 6mm, 8mm |
Wire any meters/sensor with bare wire ends to this field connect. Choose the correct size for the thickness of the meter/sensor cable.Waterproof if sealed correctly during install. |
ACC-CAB-M12-M-5 |
|
M12 Bare-Wire Cable: Male M12 5-pos connector on one end and free wires on other. |
Wire meters/sensors with terminal block connections to this accessory.The bare wire end is not waterproof unless sealed correctly. |
ACC-CAB-M12-EXT-5P-2MACC-CAB-M12-EXT-5P-3MACC-CAB-M12-EXT-5P-5MACC-CAB-M12-EXT-5P-10MACC-CAB-M12-EXT-5P-15MACC-CAB-M12-EXT-5P-30M |
|
5 Pole M12 Male to Female PUR black extension Cable. Options for cable length: 2m, 3m, 5m, 10m, 15, 30m |
Waterproof cable extensions to extend the distance between the Wildeye and your meter/sensor. |
ACC-CON-M12-2SPLIT |
|
M12 5P Y-Splitter, 1 Male and 2 Female connections, solid shell style. |
Use this part to attach 2 different meters/sensors to a Wildeye cable. |
ACC-EXP-2MAACC-EXP-MVACC-EXP-MO |
|
Wildeye Single Cable Expander modules with M12 plug cable option. Channels options: "A" (4-20mA), "V" (0-5V), "O" (10k resistance). |
Add expanders to connect additional meters/sensors to your Wildeye.Expanders can have multiple cables and channel types, for details on expander options click here. |
ACC-EXP-3LW |
|
Wildeye 3-Cable Expander modules with bare wire cable option. Channels options: "W" (watermark) |
Add expanders to connect additional Watermark sensors to your Wildeye. |
ACC-CAB-5PCOUNT |
|
5-pin M12 adaptor cable to convert new loggers with counter inputs on Pin 5 to match older sensors with with counter line on Pin 2. |
Connecting old 3G pulse-output sensors to new WILD-M loggers |
ACC-CAB-5PENV |
|
Same as ACC-CAB-5PCOUNT above, but also contains pass-through on SPO, An, & GND. |
Connecting old 3G pulse-output sensors to new WILD-M loggers |